From well to power plant, for uninterrupted energy.
Geothermal fluid, with its high temperature, dissolved gases and mineral load, stresses every piece of equipment from the well to the plant. Calcite and silica scaling reduce cross-sections, CO₂ and H₂S corrosion attacks pipes and well completions, and heat transfer drops in exchangers. The result is unplanned downtime, cleaning costs and lost production. With the BiyoGeo series developed for geothermal power plants, wells, reinjection lines and district heating systems, Biyopol Kimya aims to control scaling and corrosion at the source.
Watch the video
How to prevent scale in geothermal linesVideo in Turkish▶ Watch on YouTube
Our TÜBİTAK 1507 project: scale-inhibiting polymersVideo in Turkish▶ Watch on YouTubeThe most common problems in the field
- Calcite scaling: CO₂ breakout with pressure drop causes calcite to precipitate in downhole and surface equipment; cross-sections narrow and flow drops.
- Silica scaling: As the fluid cools, silica saturation is exceeded; hard, difficult-to-remove layers form in reinjection lines and exchangers.
- CO₂ and H₂S corrosion: Acid gases cause uniform and pitting corrosion on carbon steel, shortening the life of well completions and pipelines.
- Efficiency loss in heat exchangers: Even a thin scale layer significantly reduces heat transfer, causing capacity loss in district heating circuits.
- Unplanned downtime and cleaning cost: Mechanical and acid cleaning mean both cost and lost production; chemical prevention is more economical.
The Biyopol approach
Temperature, pH, dissolved gas and mineral content are assessed to determine inhibitor type and dose.
Product, dosing point and dose are verified first at pilot scale, then at the wellhead against measurable criteria.
The correct injection point is recommended according to the pressure/temperature zone where scaling begins.
Performance is tracked with coupons, flow and differential pressure; the dose is updated when needed.
Where do problems start in a geothermal system?
Scaling and corrosion do not occur at a single point; they take different forms along the path of the fluid from the production well to reinjection. The first step of an effective chemical programme is to identify which mechanism dominates at each piece of equipment.
| Location | Typical problem | Chemical approach |
|---|---|---|
| Production well (around the flash point) | Calcite scale, narrowing bore, falling flow rate | Continuous scale inhibitor dosing below the flash depth via capillary tubing |
| Wellhead, separator, steam lines | Calcite and mixed scales, CO₂ corrosion | Scale inhibitor + corrosion inhibitor programme |
| Binary (ORC) heat exchangers | Silica, metal silicate and sulphide deposits; loss of heat transfer | Silica control, dispersant, temperature and pH management |
| Reinjection line and well | Silica scale, loss of injectivity, oxygen-driven corrosion | Silica inhibitor/dispersant, prevention of oxygen ingress, monitoring |
| District heating and greenhouse circuits | Scale in plate heat exchangers, corrosion in closed loops | Heat exchanger conditioner, closed-loop corrosion inhibitor |
Scaling and corrosion mechanisms
Calcite (calcium carbonate) scaling
Reservoir fluid carries dissolved CO₂ under high pressure. As the fluid rises in the well and pressure drops, boiling (flashing) begins and CO₂ moves into the gas phase. Losing CO₂ raises the pH, calcite becomes supersaturated and scale builds up quickly in a narrow zone just above the flash point. Within months it can narrow the wellbore and cut flow significantly. Mechanical reaming or acid cleaning is costly and means lost production. The lasting solution is continuous injection of a scale inhibitor below the flash depth through capillary tubing.
Silica and metal silicate scaling
High-temperature reservoir water contains a large amount of dissolved silica. As the fluid cools and steam is separated, silica concentration in the remaining brine rises while the solubility of amorphous silica falls with temperature. Once saturation is exceeded, silica polymerises at a rate that depends on temperature, pH and salinity. The most affected locations are binary plant heat exchangers and reinjection lines, where the fluid is cooled the most. Where iron, magnesium or aluminium are present, harder and more persistent metal silicate layers form. Silica management needs a temperature limit, pH control and a silica-specific inhibitor/dispersant programme designed together.
Sulphide deposits
In some fields, especially in the cold end of binary plant heat exchangers, deposits such as antimony sulphide (stibnite) and iron sulphide can occur. Even thin layers reduce heat transfer noticeably. Analysing a scale sample is key to identifying the source; the programme is then based on the composition of the deposit.
CO₂ and H₂S corrosion, oxygen ingress
Dissolved CO₂ forms carbonic acid, causing general and pitting corrosion of carbon steel, while H₂S brings sulphide films and cracking risk. Oxygen is often the strongest accelerator: air entering at reinjection tanks, pump seals or district heating circuits can multiply corrosion rates. Iron released by corrosion also combines with silica and makes scale heavier, so corrosion and scale control should be designed as one programme.
Heat exchanger and ORC fouling
In binary (ORC) plants, heat is transferred to the organic working fluid through plate or shell-and-tube exchangers. Even a few millimetres of scale lowers the overall heat transfer coefficient, raises the approach temperature and reduces the plant’s net output. Regular tracking of exchanger inlet/outlet temperatures and pressure drop is the cheapest way to catch fouling before cleaning is needed.
The right dosing point: downhole capillary injection
In calcite control, half of success is the product and half is the injection point. The scale inhibitor is fed continuously through stainless-steel capillary tubing run below the depth where flashing starts, so the chemical reaches the scaling zone together with the fluid. Flash depth is calculated from wellhead pressure, the temperature profile and gas content, and is reassessed as operating conditions change. Surface equipment, heat exchangers and the reinjection line may need separate dosing points. Biyopol prepares its injection point recommendation from the field’s fluid analysis and operating data.
How is performance measured?
| Indicator | What it shows |
|---|---|
| Ca and alkalinity at wellhead and along the line | Whether calcium stays in solution, i.e. whether calcite inhibition works |
| Total and monomeric silica | Silica polymerisation tendency and inhibitor efficiency |
| Corrosion coupons and ER/LPR probes | Corrosion rate (mm/year) and level of protection |
| Flow rate, wellhead pressure, pressure drop | Bore narrowing and scale build-up |
| Heat exchanger approach temperature, heat transfer coefficient | Exchanger fouling and plant efficiency |
| Reinjection well injectivity | Scaling and plugging in the reinjection system |
| Residual inhibitor concentration | Adequate dosing and avoiding unnecessary chemical use |
Geothermal heating, greenhouses and spas
Geothermal resources are used not only for power but also for district and residential heating, greenhouse heating and thermal spas. Fluids in these systems are usually cooler, yet calcite scale in plate heat exchangers and oxygen-driven corrosion in closed loops are common. BiyoGeo HX conditioner and closed-loop corrosion inhibitors are used to extend exchanger cleaning intervals and protect circuit life.
R&D: scale inhibitor polymers developed with TÜBİTAK support
The scale inhibitor polymers of the BiyoGeo series were developed and commercialised in a project supported by TÜBİTAK’s 1507 SME R&D programme. The aim was a locally produced alternative that stays stable under the high temperature, hardness and alkalinity of Turkish geothermal fluids. See our R&D and TÜBİTAK projects page for details.
Why Biyopol Kimya?
- Manufacturer: producing since 1992 at our plant in İTOB Organized Industrial Zone, İzmir; supply and technical support from one source.
- Own R&D: polymers developed in a TÜBİTAK-supported project and designed for Turkish geothermal fluids.
- Close to the fields: our İzmir plant is a short distance from the geothermal fields of Aydın, Denizli, Manisa and İzmir, which makes site visits and sampling easy.
- Measurable programme: fluid analysis, pilot trial, wellhead verification and regular performance reporting.
- Export-ready supply: drums and IBCs; scheduled deliveries for continuous dosing.
Recommended products
- BiyoGeo CS – Calcite and silica scale inhibitor for geothermal fluids
- BiyoGeo CI – Corrosion inhibitor for geothermal wells and pipelines (CO2 / H2S environments)
- BiyoGeo HX – Conditioner for geothermal heat exchangers and district heating circuits
- BiyoCorr W – Water-soluble inhibitor for closed-loop systems
- BiyoAcid Inhibit – Metal surface protector for acid cleaning
Our products
The products below are supplied from our plant in the İTOB Organized Industrial Zone, İzmir. Contact us for technical data sheets, safety data sheets and samples.
B SCALE 73 / 74
Phosphonate and polymer based scale inhibitor against calcium carbonate (calcite) and sulphate scale. B SCALE 74 is a version with a different active content.
Applications: Geothermal wells and power plants, cooling towers, heat exchangers; continuous dosing.
P SCALE 636
Polymeric dispersant and scale inhibitor against silica and calcite scale.
Applications: Geothermal fluids with silica risk, reverse osmosis pre-treatment, closed loops.
P SCALE 115A
Polymer based, phosphonate-free scale inhibitor and dispersant.
Applications: Systems with phosphorus limits, cooling water and geothermal.
P SCALE 4036
Acrylic acid–AMPS copolymer polymerised in our plant; an effective dispersant at high temperature and salinity.
Applications: Main component in scale inhibitor formulations; dispersion of calcium phosphate, silica and iron.
Preparing for a trial: what we need from you
- Wellhead temperature, pressure and flow rate
- Fluid analysis (pH, Ca, SiO₂, CO₂, H₂S, chloride)
- Current scaling or corrosion findings and cleaning frequency
- Existing chemical programme and injection points
- Targeted improvement (less downtime, efficiency, equipment life)
In-depth technical guides
- Calcite scaling in geothermal wells
- Silica and metal silicate scaling
- Corrosion in geothermal systems
- Downhole dosing via capillary tubing
- Heat exchanger and ORC fouling
- Scaling in reinjection lines and wells
- Geothermal heating and greenhouse systems
- Sulphide scales (stibnite, iron sulphide)
Regional pages
Regional articles
Frequently asked questions
Where should the scale inhibitor be injected?
For calcite, upstream of the point where gas breakout begins, usually by deep downhole injection; for silica, in the reinjection line before the fluid cools.
Can a corrosion inhibitor be used together with a scale inhibitor?
Yes, they are used together in programmes whose compatibility has been confirmed; product selection is based on the fluid analysis.
How is performance measured?
Corrosion coupons, flow and differential pressure tracking, exchanger outlet temperatures and the change in cleaning intervals are the main indicators.
What packaging do you supply?
Depending on the product, drums and IBCs are available.
How is the scale inhibitor dose determined for a geothermal plant?
A starting dose is set from fluid analysis (Ca, alkalinity, SiO₂, pH, CO₂), the temperature–pressure profile and flow rate, then optimised during the field trial using calcium retention and pressure data. The dose is specific to each field.
Can silica scale be prevented chemically?
Silica is harder to control than calcite. Keeping reinjection temperature above the saturation limit, managing pH and applying a silica-specific inhibitor/dispersant together can markedly reduce scaling rates; the programme is designed for each field.
Do binary (ORC) plants need a different programme?
Yes. Because the fluid is cooled to lower temperatures, silica, metal silicate and sulphide deposits become dominant, so the programme focuses on heat exchangers and the reinjection line.
How do we switch from our current chemical supplier?
A compatibility test with the current product comes first, followed by a controlled changeover with parallel monitoring so production is not interrupted.
How can we request a sample or a field assessment?
Use our quote and sample form or write to info@biyopolkimya.com; we evaluate your request together with your fluid analysis.
Related product groups
Water Treatment Chemicals · Corrosion Inhibitors
Let’s trial it at your well
Share your fluid analysis and operating conditions; we will recommend a suitable programme and verify it with you in the field.